As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT, CARGO FLOOR SUPPORT, HAS CORROSION AROUND NUTPLATED AT BS 640-646, RBL 3" REMOVED CORROSION REF SRM 51-10-2. ORIGINAL MATERIAL THICKNESS .071", AFTER BLEND .010 MATERIAL REMOVED FOR A REMAINING THICKNESS OF .061 AND IS OUT OF LIMITS REF SRM 53-10-1. FABRICATED REPAIR PARTS SRM 53-10-5 AND INSTALLED REPAIR REF SRM 53-10-5 AND SRM 51-30-2.