What was found
AFT LWR CARGO PIT FUSE. CUTOUT FOR NR 3 DOOR, STA 1130 PLUS 13" AFT SIDE FRAME HAS CORROSION DOWN LOW WHERE SCUFF PLATE MOUNTS AT STR 26R. REMOVED FRAME AT STA 1130 PLUS 13, FROM STRINGER 18R-28. REPLACED WITH NEW FRAME STA 1130 PLUS 13, FROM STRINGER 18R - 28R, IN REF TO SRM 51-30-2 PG 1-17, BAC DWG 65-56132. THIS IS CLASSIFIED AS A MAJOR REPAIR.