What was found
MAIN CARGO DOOR LOWER JAMB AT NR 6 SPOOL LOCATION, ALL 4 HOLES (A, B, C, D) HAD EVIDENCE OF CORROSION. REAMED HOLES A,B,C TO 0517 AND HOLE D TO .484 TO REMOVE CORROSION IN REF TO MD/DC10-10 SRM 53-50-00 FIG 17 VOL I. ACCOMPLISHED BHEC IN REF TO NTSPM 06-10-01-003 AND FOUND HOLES B AND C WITH CRACK INDICATION. REPLACED NR 6 FITTING IN REF TO MD/DC10-10 SRM 51-33-01 VOL II PG 1 AND DAC DWG ACA 7224 REV G.