What was found
MAIN CABIN FLOOR TRACK SCALLOP BROKEN OUT AT STA 792 LBL 49. CHECK LIMITS AND IS OUT OF LIMITS IAW DC/MD10-10 SRM 53-70-00 VOL I PG 21. REMOVED SEAT TRACK IAW DC/MD10-10 SRM 51-31-01 VOL II PG 1. FABRICATED SPLICE PLATE AND SPLICE HAT IAW DC/MD10-10 SRM 53-70-00 PG 4 FIG 1 VOL I. DRILLED NEW SEAT TRACK IAW DC/MD10-10 51-31-01 VOL II PG 1. INSTALLED SEAT TRACK, SPLICE PLATE AND SPLICE HAT IAW DC/MD10-10 SRM 51-31-01 VOL II PG 1. REPAIR CLASSIFIED AS MAJOR REPAIR.