What was found
AFT CARGO COMPARTMENT FLOORBEAM AND FLOOR SUPPORT ARE EXFOILIATED AROUND NUMERIOUS NUTPLATES ON UPPER CHORDS ALONG ENTIRE LENGTH AT F/S 1841 BLENDED WORN AREAS IAW SRM 51-21-01 CHECKED LIMITS ORIGINAL MAT. .094 AFTER REWORK .078 WITHIN LIMITS ON FLOORBEAM, ON FLOOR SUPPORT ORIG MAT .063 AFTER REWORK .054 WITHIN LIMITS IAW SRM 53-00-01 FIG 1A. FOUND SECTION OF FLOORBEAM BETWEEN LBL 12 TO RBL 50 OUT OF LIMITS SPLICED NEW SECTION OF FLOORBEAM IAW SRM 53-00-01 FIG 9 VOL 1.