What was found
MAIN DECK CEILING PNL SUPPORT ANGLE IS BUCKLED/CRACKED, BS 620, LBL 14. REPLACED SUPPORT ANGLE AT BS 620, LBL 14 REF SRM 51-30-2 PG 7. FABRICATED NEW SUPPORT REF FED EX DWG 25FX1253. THIS IS CLASSIFIED AS A MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CEILING PNL SUPPORT ANGLE IS BUCKLED/CRACKED, BS 620, LBL 14. REPLACED SUPPORT ANGLE AT BS 620, LBL 14 REF SRM 51-30-2 PG 7. FABRICATED NEW SUPPORT REF FED EX DWG 25FX1253. THIS IS CLASSIFIED AS A MINOR REPAIR.