What was found
MAIN DECK CEILING PNL SUPPORT ANGLE IS BUCKLED/CRACKED BS 600, LBL 14. REPLACED SUPPORT ANGLE AT BS 600, LBL 14, REF SRM 51-30-2, PG 7. FABRICATED NEW SUPPORT REF FED EX DRAWING DWG 25FX 1253. THIS IS CLASSIFIED A MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CEILING PNL SUPPORT ANGLE IS BUCKLED/CRACKED BS 600, LBL 14. REPLACED SUPPORT ANGLE AT BS 600, LBL 14, REF SRM 51-30-2, PG 7. FABRICATED NEW SUPPORT REF FED EX DRAWING DWG 25FX 1253. THIS IS CLASSIFIED A MINOR REPAIR.