What was found
CABIN FRAME REPAIR INSTALLED AT BS 640, STR S-11R, FRAME HAS TOOLING DAMAGE ON AFT FACE OF FRAME WEB AT UPPER RIVET BUCKTAIL BLENDED DAMAGE AREA AT CABIN FRAME STA 640, STR 11R REF SRM 53-10-1 FIG 1. ORIGINAL MATERIAL .056 INCH. MATERIAL REMAINING .048 INCH'. MATERIAL LOSS OF .008 AND DAMAGE IS LESS THAN 1" FROM A HOLE IN RESPECTION NOTE "U" REF SRM 53-10-1. FABRICATED REPAIR DOUBLER REF SRM 53-10-4 FIG 1. HEAT TREATED, TRACKING NR 2008-01-073, TREATED AND PRIMED REPAIR DOUBLER AND INSTALLED REF 51-10-2, 51-30-2, 53-10-4. THIS IS CLASSIFIED AS A MAJOR REPAIR.