What was found
LWR FWD CARGO PIT FRAME, UPPER FLANGE HAS SURFACE CORROSION, AFT SIDE OF STA 720D ABOVE STR 26L. FRAME DAMAGE FOUND TO BE OUT OF LIMITS, CUT OUT DAMAGE, FABRICATED REPAIR DOUBLER AND FILLER. REMOVED AND REINSTALLED Z-ANGLE, BULKHEAD SUPPORT AND INTERCOSTAL TO GAIN ACCESS TO FRAME . IAW SRM 51-30-2, SRM 51-40-3, HEAT TREAT FOR REPAIR DONE ON 8130 TRACKING NR 2008-01-116. THIS IS CLASSIFIED MAJOR REPAIR.