As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LWR FWD CARGO PIT FRAME UPPER FLANGE HAS SURFACE CORROSION, AFT SIDE STA. 720D ABOVE STR 26R. FOUND FRAME TO BE OUT OF LIMITS. CUT OUT DAMAGE AND REPAIRED FRAME. REINSTALLED Z-ANGLE, VERTICAL BULKHEAD SUPPORT IAW SRM 51-30-2 PG 1-16 SRM 51-40-2 PG 1-6, DWG 65-58677-17, 65-58352-54. HEAT TREAT FOR FRAME DONE ON 8130 TRACKING NR 2008-01-079. THIS IS CLASSIFIED AS A MAJOR REPAIR.