As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT AT STA 879 RBL 57 FLOORBEAM HAS CORROSION. FOUND TO BE OUT OF LIMITS AND REPAIRED BY SPLICING IN NEW SECTION OF FLOORBEAM IAW SRM 53-00-01 VOL I FIG 7. THIS REPAIR IS CLASSIFIED AS MAJOR. ROLLER TRAY AT STA 765-879 RBL 56 REMOVED FOR ACCESS AND REINSTALLED IAW SRM 51-31-01 VOL II PG1.