What was found
NR 6 MCD LOWER JAMB SUPPORT FITTING HOLES A, C AND D HAS CRACK INDICATIONS FOUND WITH BHEC (SEE ATTACHED DRAWING). INSTALLED REPAIR BUSHINGS IN REFERENCE WITH DC/MD10-10 SRM VOLUME I, 53-50-00, PAGE 81 FIG 17 AT HOLE LOCATIONS A, C, AND D TO CARGO DOOR JAMB BEAM ONLY. LOWER FITTING WAS REPLACED ON NON-ROUTINE N00951. MAJOR REPAIR.