What was found
MCD SPOOL BRACKET NR 1 HAS CRACK INDICATION ON HOLES A, B, C, AND D. REAMED ALL HOLES TO DIMENSIONS SHOWN IN TABLE 1 OF EA 8-5310-113030. PERFORMED HFEC OF ALL HOLES, NO DEFECTS NOTED. IAW NDT SPM 06-10-01-003. REPAIRED LOWER JAMB BEAMS IAW EA 8-5310-113030. REMOVED JAMB SUPPORT FITTING IAW SRM 51-33-01, VOL II ,PG 1. REMOVED AND REPLACED SUPPORT FITTING IAW SRM 53-50-00 VOL I, FIG 17 & 51-33-01, VOL II, PG 1. INSTALLED INTERCOSTAL FS 635-655 IAW SRM 51-33-01, VOL II ,PG 1. MAJOR REPAIR