What was found
LT WING TO BODY FUSELAGE SKIN SURFACE SHOWS CORROSION AND GOUGE AT LAP JOINT STA 720E, STR 19L. BURNISHED AFFECTED AREA AND FOUND OUT OF LIMITS IAW SRM 53-30-1 FIG1,2. REMOVED FAIRING FOR ACCESS IAW SRM 51-30-2. CUT OUT DAMAGE DIM 43/4 X 23/4. FABRICATED DOUBLER, FILLER IAW SRM 53-30-3 FIG6 AND 53-30-2 FIG2. TREATED AND PRIMED PARTS IAW SRM 51-10-2. INSTALLED REPAIR PARTS IAW SRM 53-30--3 FIG6 AND 51-30-2. REINSTALLED BODY FAIRING IAW SRM 51-30-2.