What was found
CABIN FLOOR PANEL AT STA 555 RBL 8.5 TO 27.5 HAS EDGE DAMAGE AND HOLES. FABRICATED NEW FLOOR PANEL STA 555, POTTED EDGES, COMPETED CURE AND SANDED EDGE POTTING, INSTALLED INSERTS AND APPLIED ANTI-SKID IAW FEDEX DWG SRZ 25-005 REV F. THIS IS A MINOR REPAIR.