What was found
MAIN CABIN FLOORBOARD AT LBL - 20, BETWEEN STA 1821 TO 1881 IS SPONGY. FABBED FLOORBOARD IAW SRZ-25-005 REF F. INSTALLED FLOORBOARD IAW SRM 51-31-01 VOL II. LOCATED, DIRLLED HOLES. INSTALLED INSERTS, INSTALLED ANTISKID IAW DWG SRZ 25-005 REV F. INSTALLED FLOORBOARD IAW SRM 51-31-01, VOL II. MINOR REPAIR