What was found
FWD CARGO PIT BILGE AREA FOUND CORROSION ON THE DRAIN PAN SUPPORT ANGLE AROUND THE NUT PLATES ABOVE THE FRAME AT FS 939; STR 49L/R. REMOVED CORROSION IAW SRM 51 21-01; VOL II; PG 28. THE ORIGINAL THICKNESS IS .040 IAW DWG ADA 0145 REV J. THE MATERIAL REMOVED IS .003. THE MATERIAL REMAINING IS .037. FOUND TO BE WITHIN LIMITS IAW SRM 53-00-01; VOL II; FIG 1B. TREAT AND PRIMED IAW SRM 53-21-01; VOL II; PGS 21 AND 24; THEN INSTALLED THE NUT PLATES IAW SRM 51-35-01; VOL II; PG 2.