What was found
UPON REMOVAL OF INTERCOSTAL AT STA 1400, LBL 2, FOUND CORROSION ON BUTT SPLICE STRAP. REMOVED CORROSION IAW SRM 51-10-02, L= 1.5", W= 1.1", D=.030" SRM DOES NOT PROVIDE ALLOWABLE DAMAGE LIMITS FOR THIS PART, CONTACTED ENGINEERING. PER EA F-5330-110824: TRIMMED OUT DAMAGED AREA ON SPLICE STRAP, HFEC INSPECTED AREA, VERIFIED FRAME SHEAR TIE BETWEEN S29L AND 30 NOT DAMAGED. FABRICATED REPAIR DOUBLER AND FILLER, INSTALLED REPAIR PARTS. THIS IS A MAJOR REPAIR WITH NO FOLLOW UP ACTIONS IMPOSED BY SAID EA.