As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT FLOOR PANEL NR 187 AF REQUIRES FABRICATION PER SRZ 25-011. FABRICATED NEW FLOOR PANEL NR 187 AF; LOCATED HOLES; POTTED EDGES; COMPLETED CURE; SANDED EDGES AND INSTALLED INSERTS. FABRICATED TOP SHEET AND LAYED UP UNDER A VAC BAG; COMPLETED CURE; COUNTER SUNK HOLES AND APPLIED NON-SKID IAW SRZ 25-005; REV F AND 25-011; REV C. MAJOR REPAIR.