As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT; FS 899 SHEAR TIE AT L49L TO L51R HAS DOUBLE DRILLED HOLES. FABRICATED NEW SECTION OF THE SHEAR TIE & SHEAR TIE SPLICE SPLICE IAW DWG ADA 0112; REV P & SRM 53-30-00 VOL I FIG 10. ALODINED, PRIMED & PAINTED IAW SRM VOL II PG 8. PART MARKED IAW GMM 7-0-1000.