What was found
RIGHT WING INBD FLAP, INBD HINGE POINT IS GOUGED. BLENDED AREA. FOUND TO BE OUT OF LIMITS IAW SRM 57-00-01 AND DWG ARC 2518. REMOVED DAMAGED FAIL SAFE STRAP AND RECEIVED A NEW STRAP. LOCATED, DRILLED AND INSTALLED THE NEW STRAP IAW SRM 51-35-01, SRM 1-31-01, SRM 51-33-01& DWG ARC 2518. REMOVED BUSHING; FABRICATED / MACHINED A NEW BUSHING & INSTALLED THE NEW BUSHING IAW CMM 51-52-01. ALODINED & PRIMED IAW SRM 51-21-01.