What was found
AFT PIT FLOOR PANEL 187 JF REQUIRES FAB NEW. FABRICATED NEW FLOOR PANEL 187 JF; POTTED EDGES; COMPLETED CURE AND SANDED EDGES; INSTALLED INSERTS; FABRICATED TOP SHEET; LAYED UP UNDER VAC BAG; COMPLETED CURE; BACK DRILLED AND COUNTERSUNK HOLES; APPLIED NON-SKID AND PART MARKED PANEL IAW FEDEX DWG SRZ 25-005, REV F AND 25-011, REV C.