What was found
AFT PIT FLOOR PANEL 187 KF REQUIRES FAB NEW. FABRICATED A NEW PANEL 187 KF; POTTED EDGES; COMPLETED CURE AND SANDED EDGE POTTING; INSTALLED INSERTS; FABRICATED THE TOP SHEET; LAYED UP TOP SHEET UNDER A VAC BAG AND COMPLETED CURE; BACK DRILLED AND COUNTER SUNK HOLES; APPLIED NON-SKID AND PART MARKED PANEL IAW FEDEX DWG SRZ 25-005 REV F AND 25-011 REC C.