What was found
FWD PIT, ATTACH ANGLE ON LONGERON 52 IS CORRODED, BL O AT STA 959. CUT OUT DAMAGED SECTION OF ATTACH ANGLE (SHEAR TIE). FABRICATED A NEW SHEAR TIE SECTION AND 2 SPLICES IAW DC/MD-10 SRM 53-30-00, VOL I, FIG 9 AND 10. ALODINED, PRIMED AND PAINTED SHEAR TIE SECTION AND SPLICES IAW DC/MD-10 SRM 51-21-01, VOL II, PGS 21 - 24 AND SRM 51-21-02, PG 8, VOL II. INSTALLED THE NEW SHEAR TIE SECTION AND SPLICES IAW DC/MD-10 SRM 51-33-01, VOL II, PG 34 AND SRM 51-35-01, VOL II, PG 1.