What was found
TAILCONE ACCESS PANEL, CUT OUT, FWD EDGE LATCHING POSITIONS ARE MISSING MATERIAL IN 2 PLACES. FABRICATED A NEW ATTACH ANGLE IAW DC/MD-10 SRM 53-52-01, VOL III AND DAC DWG NRC 6022. ALODINED AND PRIMED ANGLE IAW DC/MD-10 SRM 51-21/01, VOL II. REMOVED AND INSTALLED ANGLE IAW DC/MD-10 SRM 51-35-01, VOL II.