What was found
NR 3 PYLON PANEL 487 CL HAS A CHAFED RIB. BLENDED RIB IAW SRM 54-00-01; VOL I. FOUND TO BE OUT OF LIMITS IAW SRM 54-00-01; VOL I. LOCATED AND DRILLED HOLES IAW DWG AUB 7080; REV A. ALODINED AND PRIMED IAW SRM 51-21-01; VOL II. MARKED PART AUB 7080-3 IAW GMM 7-0-1001. INSTALLED AUB 7080-3 IAW DWG AUB 7080, REV A.