As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CARGO DOOR JAMB AT SPOOL FITTING NR 1, HOLE "A" IS OVERSIZED TO 0.536 INCH. REMOVED SUB STRUCTURE AND WEB TO GAIN ACCESS TO THE NR 1 SPOOL BACK UP FITING IAW SRM 51-31-01;VOL II. LOCATED AND DRILLED NEW BACK UP FITTING AFA 7135-1IAW SRM 51-31-01; VOL II. INSTALLED NEW BACK UP FITTING IAW SRM 51-33-01; VOL II. INSTALLED SNU STRUCTURE AND WEB IAW SRM 51-33-01; VOL II. INSTALLED BUSHING IAW SRM 53-50-00, VOL I.