What was found
MAIN CARGO DOOR JAMB AT SPOOL FITTING NR 2, HOLE "D" IS OVERSIZED TO 0.545 INCH. REMOVED WEB AND STRUCTURE IN REF TO DC/MD-10 SRM 51-33-01; VOL II AND 51-35-01; VOL II. REMOVED BACK UP FITTING IN REF TO DC/MD-10 SRM 51-33-01; VOL II. LOCATED AND DRILLED THE BACK UP FITTING IN REF TO DAC DWG AFA 7132; REV "B". INSTALLED BACK UP FITTING, REF TO DC/MD-10 SRM 51-33-01; VOL II. INSTALLED BUSHING ON THE BEAM IN REF TO EA 8-5310-117003 "FUSELAGE, MAIN DECK CARGO DOOR JAMB LOWER SEAL OVERSIZED HOLES AT THE NR 1 AND NR 2 SPOOL FITTINGS REPAIR".