What was found
LEFT HORIZONTAL STAB L / E PANEL 341 AB OUTBD BOTTOM FORMER IN CRACKED. STOP DRILLED THE CRACK IAW SRM 51-23-10. HFEC STOP DRILL PER NTW 51-10-08. VERIFIED THE CRACK STOPS. FABRICATED & INSTALLED REPAIR ANGLES IAW SRM 55-12-19.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT HORIZONTAL STAB L / E PANEL 341 AB OUTBD BOTTOM FORMER IN CRACKED. STOP DRILLED THE CRACK IAW SRM 51-23-10. HFEC STOP DRILL PER NTW 51-10-08. VERIFIED THE CRACK STOPS. FABRICATED & INSTALLED REPAIR ANGLES IAW SRM 55-12-19.