What was found
THE CENTER LANDING GEAR SPAC, LONGERON FITTING, RIGHT SIDE FROM STA 1501 TO 1521 IS CORRODED. REMOVED FITTINGS IAW SRM 51-33-01. REMOVED CORROSION & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01. REMOVED CORROSION & FOUND OUT OF LIMITS IAW SRM 53-00-01. MACHINED FITTING IAW DWG AYB7020. REMOVED CORRODED SECTION, FABBED NEW LONGERON SECTION & REPAIR SPLICES IAW DWG AYB 7013 & SRM 53-00-01. INSTALLED LONGERON SECTION, REPAIR SPLICES & END FITTINGS IAW SRM 53-00-01 & 51-31-01.