What was found
FWD CARGO PIT STA 760 STR -24L FRAME UPPER J ANGLE DENTED. REPAIRED FRAME STA 760 STR -24L IAW SRM 53-00-07,51-40-02. SUBSEQUENT INSPECTIONS ARE REQUIRED PER SRM 53-00-07, PAGE 208, REPAIR 5, DETAIL III AND PAGE 210, TABLE II. THIS IS A CLASS "B" REPAIR WITH FOLLOW UP INSPECTIONS REQUIRED. HFEC AND DETAILED INSPECTION REQUIRED EVERY 12,000 FLIGHT CYCLES REF 53-00-01, FIG 201, SHEET 10 OF 15,TABLE II.