What was found
WHILE C/W STRUCTURAL INSPECTION 53-10-02, FOUND .5 INCH CRACK IN OUTER FLANGE RADIUS OF INTERCOSTAL PN 114-430116-7 AT STATION NR 498.25 AND ADJACENT TO THE CARGO DOOR AFT UPPER GAS STRUT ATTACH BRACKET MOUNTED TO THE DOOR FRAME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE C/W STRUCTURAL INSPECTION 53-10-02, FOUND .5 INCH CRACK IN OUTER FLANGE RADIUS OF INTERCOSTAL PN 114-430116-7 AT STATION NR 498.25 AND ADJACENT TO THE CARGO DOOR AFT UPPER GAS STRUT ATTACH BRACKET MOUNTED TO THE DOOR FRAME.