SDR 1392100204

Service difficulty report · Sensor · Gulstm GIV

Difficulty date
October 2, 2004
Submitted
November 17, 2004
Operation
Air carrier
Aircraft
N492QS
Make and model
Gulstm GIV
Aircraft serial
1392
Engine
Rroyce TAY6118
Part
Sensor
Part number
6006508
Condition
Failed
Location
Brake Temp
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BRAKE OVERHEAT (AMBER) MASTER CAUTION LIGHT CAME ON. BRAKE PAGE CONFIRMED A LT WHEEL (RT SIDE BRAKE) OVERHEAT WILL TEMP ABOVE 800 DEG. THEN, THE INDICATION WENT TO 252 DEG FOR THAT SAME BRAKE AND THE TEMP OVERHEAT AMBER LIGHT WENT OUT. THE TEMP LATER STARTED TO CLIMB SLOWLY. AT 285 DEG, THE TEMP SPIKED TO ABOVE 800 DEG WITH THE BRAKE OVERHEAT LIGHT COMING ON AGAIN. DURING DECENT FOR PRECAUTIONARY LANDING THE TEMP DROPPED BACK TO 285 DEG, (NOT LONG AFTER RE-SPIKING) JUST PRIOR TO TOUCHDOWN, THE BRAKE TEMP WENT TO NORMAL AT 31 DEG AND STAYED THERE UNTIL SHUTDOWN. FOUND BRAKE TEMP SENSOR FAILED, REMOVED AND REPLACED. OPS CHECKED GOOD. MX IAW GIV CMPCODE 324297.