Service difficulty report · Control Cable · Amrgen AA5A

Difficulty date
March 8, 2000
Submitted
March 30, 2000
Operation
General aviation
Aircraft
N26086
Make and model
Amrgen AA5A
Aircraft serial
AA5A0326
Part
Control Cable
Condition
Damaged
Location
Pulley Cluster
Part time
3,500 hours
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING ANNUAL INSPECTION, FOUND CABLES DETERIORATED AND FRAYED AS WOULD BE FOUND IF INSPECTING SERIES AS AN AA1, AS SPECIFIED IN AD 72-6-2. AS THE REST OF THE GRUMMAN SINGLE ENGINE FLEET HAS SIMILAR CABLE RUNS AS THE AA1 SERIES AND THE EARLY AA5''''S WITH EARLIER S/N''''S, AD 72-06-02 SHOULD BE AMENDED TO INCLUDE ALL TYPE SERIES THAT EMPLOY THE SIMILAR PULLEY CLUSTER JUST AHEAD OF THE FRONT SPAR IN THE CABIN. WEAR APPEARS TO BE FROM NORMAL OPERATIONS/AGE OF CABLES. NORMAL ACCUMULATIONS OF DEBRIS AND DIRT IN AREA OF PULLEYS AND THE PULLEYS WERE NOT FROZEN. DUE TO THIS INSTALLATIONS DESIGN.