What was found
EN ROUTE FROM MDW TO MCO, LEADING EDGE AMBER FLAP LIGHT ILLUMINATED WHEN FLAPS ARE AT 2 DEGREES. VERIFIED SLATS 2, 3, 6, 7 INTRANSIT AT FLT ENGINEERS FLAP/SLAT PANEL. RETURNED TO MDW WITHOUT FURTHER INCIDENT. REPLACED LEADING EDGE FLAP AND SLAT CONTROL VALVE IAW 27-81-81, OPS CHECKED GOOD. (M)