What was found
(ORIG-CLOSED) LT FORWARD WINDOW HEAT INOPERATIVE. MAINTENANCE FOUND WIRES BURNED ON TB5031. INSTALLED NEW TERMINAL BOARD TB5031. RETERMINATED AND REINSTALLED WIRES IAW WDM 24-51-11 AND 24-21-14. OPERATIONAL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(ORIG-CLOSED) LT FORWARD WINDOW HEAT INOPERATIVE. MAINTENANCE FOUND WIRES BURNED ON TB5031. INSTALLED NEW TERMINAL BOARD TB5031. RETERMINATED AND REINSTALLED WIRES IAW WDM 24-51-11 AND 24-21-14. OPERATIONAL CHECKS GOOD.