What was found
INSP ON STOP-TO-STOP TRAVEL OF LT AILERON, NOTICED ODD DOUBLE BUMP SOUND, MVMT AT STOPS. LT WINGTIP, AILERON WERE REMOVED TO FACILITATE FURTHER INSP. IB AILERON HINGE MOVED UP AND DOWN WITH FORCE APPLIED TO IT. VERT MVMT (0.053”) WAS MEASURED APPROX AT BRG IN HINGE ABOUT 5 INCHES AFT OF TWO MNTING BOLTS. TORQUE-SEAL WAS STILL ON NUTS, TORQUE WAS CHECKED FIRST IN TIGHTENING DIRECTION, THEN IN LOOSENING DIRECTION. TORQUE REQUIRED TO TIGHTEN UPPER NUT WAS 75 INCH LBS, AND 55 INCH LBS TO LOOSEN. TORQUE REQUIRED TO TIGHTEN LOWER NUT WAS 40 INCH LBS AND 37 INCH LBS TO LOOSEN. BOLTHOLES IN AILERON HINGE, PULLEY BRACKET, AND FLAP HINGE WERE MEASURED FOR ELONGATION. HOLES WERE NOT ELONGATED; LARGEST DIA FOUND WAS