What was found
WHILE CONDUCTING AN ANNUAL INSPECTION PRIOR TO PLACING THE AIRCRAFT ONLINE AFTER PURCHASING IT FROM A LOCAL OPERATOR THE LT AILERON BALANCE CABLE WAS FOUND TO BE BADLY WORN AND FRAYED. THE LOCATION OF THE FRAYING WAS AT THE 1ST IB PULLEY IN THE WING ROOT. THIS IS A KNOWN AREA OF WEAR FOR ALL PA 28, 34, AND 44 MODEL AIRCRAFT. RESEARCH OF THE MAINTENANCE RECORDS SHOWED THAT THE PREVIOUS OWNERS HAD FAILED TO COMPLY WITH SB WHICH REQUIRES REPETITIVE INSPECTIONS OF ALL FLIGHT CONTROL CABLES. THIS SB WAS APPLICABLE TO THIS AIRCRAFT. (K)