What was found
DENT UNDER LT WING 6 FEET OUTBD OF NR 1 PYLON AND 5 FT AFT OF FUELING PANEL. IT MEASURES 3-16TH DEEP AND APPROX 2 INCHES DIAMETER. VISUALLY INSPECTED AREA, PREFORMED HFEC AND FOUND NO DEFECTS. MATERIAL LOSS MEASURED AT .040" STRGR 18 BS 630, BEYOND LIMITS OF TABLE 1 OR 2 SRM 57-20-01. LEFT WING LOWER SURFACE WAS FOUND REWORKED ON OUTER WING INSPAR SKIN PANEL NR 3 AT WSTA, L-18 STRINGER,SURROUNDING STRINGER FASTNER. DAMAGED AREA IS APPROX 1.75 IN DIA AND HAS BEEN BLENDED PRIMED AND PAINTED. APPEARS TO BE CORR REWRK. .APPROVED AS PERMANENT REP AIR PER EVA-60348 AND FAA FORM 8100-0 (REF SR 1-19590868-6 AR-63 5797 05-31-06) NO FURTHER ACTION IS REQUIRED,