As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOOR 1R MED EVACUATION SLIDE ELECTRICAL HARNESS IS INCORRECTLY ROUTED. [SUP 05-16-07] REINSTALLED ELECTRICAL HARNESS CORRECTLY. SLIDE IS ORIGINAL EQUIPMENT FROM WHEN AIRCRAFT WAS DELIVERED AND THERE IS NO EVIDENCE OF THE SLIDE EVER BEING SERVICED TO THE EXTENT THAT DISTURBANCE OF THE WIRING HARNESS WAS REQUIRED. UNABLE TO DETERMINE IF THE HARNESS MISROUTE IS AN ERROR FROM THE FACTORY OR DUE TO AN INTERMEDIATE SERVICING.