What was found
FOUND NR 1 ENG IDG DELTA P SWITCH POPPED WITH METAL IN FILTER. SUSPECT BEARING OR GEAR FAILURE DUE TO METAL FOUND IN FILTER. REPLACED NR 1 ENG IDG PER MM 24-11-01, LEAK AND OPS CHECK OK. AC OK FOR SERVICE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND NR 1 ENG IDG DELTA P SWITCH POPPED WITH METAL IN FILTER. SUSPECT BEARING OR GEAR FAILURE DUE TO METAL FOUND IN FILTER. REPLACED NR 1 ENG IDG PER MM 24-11-01, LEAK AND OPS CHECK OK. AC OK FOR SERVICE