FWD EQUIPMENT OVERHEAT EICAS MESSAGE CAME ON PASSING 10000 FEET AND EXTINGUISHED PASSING 18000 FT. SUSPECT FAULTY COOLING OVERRIDE VALVE. REPLACED FWD E&E COOLING OVERRIDE VALVE PER MM 21-58-20. OPS CHECK OK. AC OK FOR SERVICE.