What was found
AFTER GEAR EXTENSION, RT MLG DOWN LIGHT FAILED TO LIGHT. PROBLEM FOUND IN WIRING HARNESS AT RT MLG DOWNLOCK SWITCH. WIRE INSIDE THE CASTING AT THE WIRING HARNESS WAS BROKEN.