Service difficulty report · Wire

Difficulty date
June 5, 2009
Submitted
August 14, 2009
Operation
General aviation
Part
Wire
Condition
Damaged
Location
Lav Water Heater
Component
Water Heater
Component part number
14591
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A TIA WATER HEATER, PN 500-0576-02, INSTALLED IN ACFT WAS RETURNED TO THE REPAIR STATION FOR INVESTIGATION. DURING THE INVESTIGATION, IT WAS LEARNED THAT REASON FOR REMOVAL WAS SMOKE IN THE CABIN AND ELECTRICAL SMELL. INVESTIGATION FOUND A BURNED CRIMP IN THE WINDOW SPLICE CONNECTING THE 16 AWG HEATER WIRES TO THE OVERHEAT TERMOSTAT. ONLY THE SINGLE WINDOW SPLICE CRIMP SHOWED EVIDENCE OF DAMAGE. ROOT CAUSE WAS DETERMINED TO BE WIRES NICKED DURING INITIAL ASSY STRIPPING. A SB IS BEING WRITTEN WHICH WILL INCLUDE A RECALL OF WATER HEATERS IN THAT PRODUCTION LOT. THE WIRE STRIPPING PROCESS IS BEING REVIEWED TO PREVENT RECURRENCE OF THE FAILURE.