What was found
DURING LANDING GEAR EXTENSION, ECAM DISPLAYED L/G LGCU 1&2 FAULT. ECAM PROCEDURE COMPLETED AND LANDING GRAVITY EXTENSION PROCEDURE COMPLETED. REMOVED AND REPLACE NLG SENSING MECHANISM AND PROX SENSOR 24GA & 25GA AND TARGETS PER MM 32-21-45-400-801A,32-31-73-200-002A. GEAR SWING CHECK GOOD PER MM 32-31-00720-002A. REMOVED AND REPLACED LGCUI 2 PER MM 32-31-71-400-001A POS CHECK GOOD PER MM 32-31-71-000-001A ALL WORK ACCOMPLISHED ON AERSALE W/O 000869 CARD 20002, 20004