What was found
REMOVED FUEL SERVO INLET STRAINER, FROM THE FUEL SERVO FOR 100HR CLEANING AND INSPECTION. WELDS HOLDING FILTER ELEMENT TO END FITTINGS WERE COLD, LACKING PENETRATION, AND CRACKED. THE WELDS ARE DOWNSTREAM SIDE OF THE FILTER. INSPECTION OF WELDS UNDER MAGNIFICATION SHOWED MULTIPLE CRACKS, FISSURES, AND POSSIBLE MISSING WELD MATERIAL, WHICH WOULD BE PASSED DOWNSTREAM INTO THE FUEL SERVO METERING SYSTEM.