What was found
EGT EXCEEDENCE LEFT ENGINE @ 200 FT ON TAKEOFF ~ CORRECTIVE ACTION: FOLLOWED FIM 71-05 TASK 806. ENGINE TEMPS AND EXCEEDENCE TIME WITHIN LIMITS. ALL INSPECTIONS AND TEST COMPLETED. NO DEFECTS NOTED AT THIS TIME. ENGINE IDLE RUN SHOWN NO SIGNS OF ISSUES. DURING INSPECTION FOUND TURBINE OVERHEAT DETECTOR CONNECTOR STUD SPINNING ON LEFT ENGINE. REMOVED AND REPLACED LEFT ENGINE IP TURBINE OVERHEAT THERMOCOUPLE PER AMM 77-22-11.