What was found
1 AREA OF CORROSION FOUND ON E-EXIT OUTER SKIN, UPPER /AFT CORNER. MECHANICALLY REMOVED 1 AREA OF CORROSION LOCATED ON E-EXIT, EXTERIOR SKIN, UPPER AFT CORNER AREA IAW C680 SRM 51-70-02. FOUND CORROSION BLEND TO BE BEYOND SRM LIMITS IAW C680 SRM 51-70-02 EXCEEDING .002" OF MATERIAL REMOVED FROM NOMINAL THICKNESS. REPAIRED CORROSION BLEND IAW NETJETS ENGINEERING RFTS-114422 REV 0. TITLE: N357QS (680-0155) EMERGENCY EXIT DOOR CORROSION,