What was found
MECHANICALLY BLENDED 7 AREAS OF CORROSION LOCATED BELOW AFT BAGGAGE FLOOR BETWEEN FS501.25 AND FS519.37 IAW SRM 51-70-02. FOUND 5 AREAS OF CORROSION BLENDING TO BE WITHIN LIMITS IAW SRM 51-70-02. PROTECTED BARE METAL IAW C680 SRM 51-20-01. THIS IS A PSE AREA IAW SRM 51-00-01. PER NJA GMM 2.1.2 THIS IS LEVEL 1 CORROSION. FOUND 2 AREAS OF CORROSION BLEND TO BE BEYOND LIMITS IAW SRM 51-70-02 EXCEEDING 0.002" OF MATERIAL REMOVED FROM NOMINAL THICKNESS.