What was found
MECHANICALLY BLENDED 12 AREAS OF CORROSION LOCATED BELOW AFT BAGGAGE FLOOR BETWEEN FS519.37 AND FS534.70 IAW SRM 51-70-02. FOUND 10 AREAS OF CORROSION BLENDING TO BE WITHIN LIMITS IAW SRM 51-70-02. PROTECTED BARE METAL IAW C680 SRM 51-20-01. THIS IS A PSE AREA IAW SRM 51-00-01. PER NJA GMM 2.1.2 THIS IS LEVEL 1 CORROSION. FOUND 2 AREAS OF CORROSION BLENDING TO BE BEYOND LIMITS IAW CESSNA 680 SRM 51-70-02. EXCEEDING 0.002" OF MATERIAL REMOVED FROM NOMINAL THICKNESS. REPAIRED CORROSION BLEND IAW NETJETS ENGINEERING RFTS-114465 REV. 0, TAIL CONE SKINS UNDER BAGGAGE FLOOR. PAGE 6, AREAS #6 AND #7 ON FIGURE 1 DATED 20AUG25.